Analysis of power failure of induction melting furnace

Fault phenomenon: the equipment works normally, but the power can't go up

Analysis and treatment: if the equipment works normally, it can only show that all parts of the equipment are in good condition. If the power is not adjusted properly, it means that the parameters of the equipment are not adjusted properly

1. The rectifier part is not adjusted properly, the rectifier tube is not fully connected, and the DC voltage does not reach the rated value, which affects the power output

2. If the voltage value is too high or too low, the power output will be affected

3. Improper regulation of cut-off and cut-off pressure results in low power output

4. The furnace body is not matched with the power supply, which seriously affects the power output

5. If there are too many or too few compensation capacitors, the power output with the best electrical and thermal efficiency can not be obtained, that is, the best economic power output can not be obtained

6. If the distributed inductance of the intermediate frequency output circuit and the additional inductance of the resonant circuit are too large, the maximum power output is also affected